tek intonat®-controls

From the simplest open and close options to fully automated manageable systems,
tek intonat®-controls provides the solution to meet your requirements for natural ventilation control.


Throughout the entire process, from defining your control requirements to final testing and commissioning, we will provide professional and technical guidance to ensure your tek intonat®-ventilation control system performs as required, using some of the latest technology available.


Manual Positioning Unit

  • Low voltage 24V AC/DC operation, 0-10VDC signal.
  • Louvres/Dampers can be manually positioned to one of six positions at anytime, including fully open and fully closed.
  • Optional auto close energy saving feature.
  • LED feedback display of louvre/damper position selected.
  • Wall/Control panel mountable.
  • Optional rain sensor to automatically close louvres/dampers where necessary.
  • Can operate multiple louvres/dampers depending on power supply unit rating.

Standard power supply unit sizes:

  • PSU8 up to 8 Actuators
  • PSU30 up to 30 Actuators

Standalone Controllers

 Our unique range of standalone controllers can control ventilation dampers or automated windows together with localised heating, via on board, temperature or optional CO2 sensors to suit the requirements of each specific application. 

  • 0/10 VDC heating signal
  • 0/10 VDC cooling/ventilation signal
  • Frost protection
  • Room temp set point adjustable 19°C to 26°C
  • Room CO2 set point adjustable 900ppm to 1600ppm
  • Pre-wireable base and plug-on fascia plate assists in easy, time saving installation.

These controllers can be linked to either a time clock or receive a time signal from a BMS to activate the optional night cooling programme (night cooling only available with the manual override options).

C: Controller, T: Temperature, C: Carbon Dioxide, m: Manual Push Buttons, I: CO2 Indication

Temperature Control

The room set point for the control of the ventilation dampers/automated windows can be adjusted in 1°C increments between 21°C and 26°C with a seasonal change over and a night cooling option if a time clock or BMS time signal is available.

Localised heating can also be controlled and is set 2°C below the room set point.

Manual Overide (optional)

Each room device has manual override capabilities which give the end user control of the ventilation strategy to suit the room application.

The device consists of two push buttons and three LED lights, the push buttons enable the end user to open or close the ventilation as required, the LEDs give an
indication that the system has either been overridden or is in Auto mode. Once the system has been overridden it will stay in that mode for 30 minutes, after this time the system will revert back to Auto mode.

CO2 Indication (optional)

Each room device can also be fitted with a further 3 LEDs to identify the level of CO2 within the space; these are green, amber and red. With green being healthy and red being high levels of CO2 ppm`s.

Night Cooling

To enable the Night cooling pre-programmed software, the device needs to be in (Night Mode) and the night cooling enabled, this then cools the building to just below the room set point. When the time switch is in (Night Mode), by holding down the open/close buttons this will enable this mode to be turned on/off.
(Indicated by the Auto LED ON or OFF).

Summer/Winter

The Summer set point can be selected to be below the Winter set point, this is 2C below that set value on the dip switches. To select Summer mode, in (Day Mode) hold both the open/close buttons down for 5 seconds, lights flash, push the open button for Summer mode, or close button for Winter mode.

Four Zone Power Supply Unit (PSU) + Time Switch (TS) Interface Unit

This interface unit comprises of a power supply, coded terminals, frost protection feature, optional digital time switch and night cooling (operated by the time switch or external VFC).

Window Control

The Window Control Module contains a 24v DC Power Supply and an iWAC module per Window Actuator that controls via a 0/10 VDC positioning signal from a suitable controller.

The WCM features an intelligent ‘self stroking’ operation and controls the 24v DC window actuator in steps to prevent noise disturbance to end users.

The Window Control Module allows only one window to operate at time. This saves the expense and space in only needing a DC power supply rated for the largest actuator (maximum 3 Amp per controller) to be operated.

The All New NV8 Natural Ventilation Controls Package

Cookie Policy

Our website uses cookies, as almost all websites do, to help provide you with the best experience we can. Cookies are small text files that are placed on your computer or mobile phone when you browse websites.

If the settings on your software that you are using to view this website (your browser) are adjusted to accept cookies we take this, and your continued use of our website, to mean that you are fine with this. Should you wish to remove or not use cookies from our site, you can learn how to do this here, however doing so will likely mean that our site will not work as you would expect.